Acta Scientific Pharmaceutical Sciences (ASPS)(ISSN: 2581-5423)

Research Article Volume 5 Issue 3

Development of a Novel Method for Determination of Risperidone in Pharmaceutical Products and its Quality Control Application

Mohamed Raslan1,2, Sara AS2, Eslam MS2 and Nagwa A Sabri1*

1Department of Clinical Pharmacy, Faculty of Pharmacy-Ain Shams University, Cairo, Egypt
2Drug Research Centre, Cairo, Egypt

*Corresponding Author:Nagwa A Sabri, Department of Clinical Pharmacy, Faculty of Pharmacy-Ain Shams University, Cairo, Egypt.

Received: February 13, 2021; Published: February 27, 2021

Abstract

Background: Risperidone is an antipsychotic drug that is selective to dopamine D2 and serotonin 5-HT2A receptors and used in the management of schizophrenia, and bipolar mania.

Aim: The work objective was to establish a specific, accurate, and sensitive analytical method for the quantification of risperidone in pharmaceutical dosage forms. The method will be used as a quality control tool for testing pre-market and post-market distribution of risperidone products, ensuring that the dosage forms are fulfilling the required labeled amount of the drug.

Methods: Evaluation of risperidone in commercial pharmaceutical products administered in hospitals, community pharmacies, and other health care facilities by the development of a high-performance liquid chromatographic (HPLC) method to add a validated sensitive and selective method to literature methods.

Results: The method showed specificity, sensitivity, and selectivity, and linearity (R2>0.999) within concentration range of 0.2 to 6 µg/mL for dissolution medium USP (0.1N HCl), and 0.1 to 3.4 µg/mL for dissolution medium pH1.2, 4.5, and 6.8. Accuracy percentage within 98 - 102%, and precision percentage below 2%. The mean recovery of assayed tablets is 100.113%. In addition, dissolution results meet the required 80% dissolution limit within 10 minutes.

Conclusion: The developed analytical technique is fully validated and applicable for use in the quantitative analysis of risperidone.

Keywords: Risperidone; Analytical Method; Schizophrenia; Bipolar Mania; Pharmacopeia; Dissolution; Validation

Introduction

  Risperidone is an antipsychotic drug that acts as an antagonist for dopamine D2 and 5-HT2A receptors. Risperidone displayed remarkable therapeutic efficacy in the treatment of schizophrenia and bipolar mania in adults [1].

  Risperidone is currently one of the most widely used antipsychotic medications for the management of acute schizophrenia and in long-term maintenance. It showed better clinical efficacy in psychotic symptoms treatment than many first-generation antipsychotics [2].

  Oral risperidone treatment showed a significant clinical outcome in reduction of autistic disorder associated irritability and other behavioral symptoms in children and adolescents maintained for up to 6 months. The drug showed good tolerability, and adverse effects can be clinically managed. Most adverse events are mild to moderate. Some adverse effects like weight gain, hyperglycemia, and somnolence require to be monitored [1].

  Clinical studies showed a significant clinical improvement after short-term therapy with risperidone in approximately 50 to 60% of patients with acute exacerbations and chronic schizophrenia. Risperidone sowed to be as effective as haloperidol and perphenazine in schizophrenia symptoms alleviation. Besides, it shows an advantage over haloperidol in a lower incidence for extrapyramidal side effects [3].

  Also, evidence from the literature suggests that risperidone provides a small benefit in treating aggression, psychosis, and agitation in dementia patients. This benefit showed to be statistically significant compared to placebo [4].

  Several methodologies for the evaluation of risperidone in pharmaceutical preparations were mentioned in several studies. The techniques include chemiluminescence [5], RP HPLC [6], TLC [7], and visible spectrophotometry [8], HPLC combined with capillary electrophoresis, HPLC-PDA, LC/MS/MS, and NMR spectroscopy [9].

  In our work, the presented validated developed method is a specific, sensitive, precise, and accurate for estimation of risperidone in dosage forms and in tablet dissolution test. Analytical method validation was carried out following FDA and ICH guidelines [10,11]. Tablet potency testing, dissolution procedures, and criteria were carried out following FDA, BCS Guidelines [12], and United States Pharmacopeia (USP) [13].

  Performing in-vitro assay testing, dosage units uniformity and dissolution is an essential step in determining the reliability of the dosage form for the intended use. In addition, assessing dosage form behaviour prior to conducting bioequivalence studies, if necessary. Drug assay should be within 90 to 110 percent of the labeled claim, and the dissolution should be not less than 80 percent of the dissolved drug within 10 minutes to guarantee that risperidone orally disintegrating tablets are valid and safe for use in order to achieve the required therapeutic efficacy.

  Routine random drug samples should be picked from the hospital and community pharmacies and exposed to quality control checks to confirm that the formulation retains its integrity and that the quantity of the active ingredient meets the required specification after being subjected to market transport conditions and shelf storage in pharmacies.

  Finally, it was impossible to rely on accurate investigations of risperidone in pharmaceutical products unless a valid analytical method was well developed for active substance determination. These routine checks are intended to guarantee that a valid and safe medicinal product is administered to patients in order to achieve the desired therapeutic outcomes and to avoid the incidence of drug toxicity or adverse reactions.

Materials and Methods

  Quality control testing like potency and dissolution testing are performed on a randomly selected samples from the market to ensure that the formulation preserves its integrity and no degradative product formation, and the active ingredient quantity complies with the specified requirements after being exposed to market transport conditions and shelf storage in pharmacies. The objective is to guarantee that patients are given safe and valid drug products in order to achieve the required therapeutic efficacy and to avoid potential drug toxicity or adverse effects.

Media preparation

  Risperidone USP reference standard. All solvents were of the HPLC grade and were purchased from Merck (Germany). The remaining chemicals used were of AR grade and were bought from Scharlab (Spain).

Analytical methods Instrumentation

  The analytical procedures were carried out using BOECO portable pH meter, Sartorius analytical balance, the HPLC Thermo Spectra System 4000 HPLC system, equipped with P4000 Gradient Pump, Autosampler with a 100 μl loop and the P1000 UV-Detector. Data processing was carried out by Chromoquest version 4.2 Software. The column used for chromatographic separation was water symmetry C8 with 5μm particles 150 mm x 4.6 mm.

  The eluting solvent was vacuum-filtered via a 0.45 μm membrane filter and degassed with Sonication prior to use. Water was purified by the water purification system ELGAPURE (England).

Chromatography conditions

  The eluting solvent consisted of 0.1% TFA: acetonitrile (70:30 V/V), with a flow rate of 1 ml/minute. Chromatographic peaks have been monitored at 280nm. Sample analysis was conducted at room temperature, and the injection volume was set at 50 μL.

Preparation of stock and standard solutions

  A 100 μg/ml master solution of risperidone was prepared by weighing 10 mg of risperidone standard into a 100 ml volumetric flask and dissolving 70 ml of methanol. The final volume was completed with methanol. 10 ml aliquot from the standard master solution of risperidone were transferred using A-grade pipettes into a 100 ml volumetric flask and solution were made up to volume with methanol to obtain a solution containing 10 ug/ml. Aliquots were transferred from this solution to a 10ml volumetric flask. After that the solutions were completed to volume with mobile phase to obtain concentrations of 0.2 to 6 μg/ml.

Method validation

  The validation of the in-house HPLC method was carried out following ICH guidelines.

Specificity

  Specificity means that method of analysis is capable of determining the target analyte in the presence of all potential impurities. Stress studies were conducted at a concentration of 4 μg/mL of risperidone active substance and formulated tablet samples to indicate stability and specificity of the method of analysis developed. Intended drug degradation was done under heat stress conditions (exposed at 85°C for 1 hour), acidic condition (1N HCl for 1 hour at 85°C) and Alkaline condition (1N NaOH for 1 hour at 85°C).

Linearity

  Linearity of the analytical method was studied by preparing triplicates of standard solutions of the target analyte at eight concentration levels from 80 to 120% i.e. Concentrations ranging from 0.2 to 6 µg/ml for USP dissolution condition, and from 0.1 to 3.4 µg/ml for dissolution conditions pH1.2, 4.5, and 6.8 [10,11].

Precision

  Precision is the evaluation of intra-day variability in results obtained at three concentrations, with nine measurements on the same day. precision is expressed by calculated RSD percent [10,11].

Detection Limit (LOD) and quantitation limit (LOQ)

  They are the analyte concentrations that would yield signal-to-noise ratios of 3 for LOD and 10 for LOQ respectively. Detection and quantitation limits were determined by the regression lines y-intercepts standard deviation and the calibration slope [10,11].

Estimation of risperidone in pharmaceutical dosage form

  To determine the assay of risperidone in orally disintegrating tablet (labeled claim: 2 mg risperidone) not less than 13 orally disintegrating tablets were weighed and transferred to a 250ml volumetric flask. 150ml of diluent (Methanol: 0.1 N HCl 40:60) were added. Sonication with intermittent shaking was performed for 30 minutes. Then the flask was left to cool at room temperature. The volume was made up with diluent, and nylon filter (0.45 μm) was used in solutions filtration. 50μl of the prepared samples were injected into HPLC-UV in triplicates. Risperidone UV detection was determined at 280 nm. Drug concentrations were estimated by comparing sample chromatographic response with that of the standard.

Estimation of risperidone content uniformity in pharmaceutical dosage form

  To determine the content uniformity of risperidone in tablets (labeled claim: 2 mg risperidone) ten orally disintegrating tablets were weighed and transferred each one individually to a 100ml volumetric flask. 50ml of 0.1N HCl was added. Sonication with intermittent shaking was performed for 30 minutes at 40oC. Then the flask was left to cool at room temperature. The volume was made up with diluent, and nylon filter (0.45 μm) was used in solutions filtration. 50μl of the prepared samples were injected into HPLC-UV in triplicates. Risperidone UV detection was determined at 280 nm. Drug concentrations were estimated by comparing sample chromatographic response with that of the standard.

In-Vitro dissolution testing determination of risperidone in pharmaceutical dosage form

  Procedures of dissolution testing were applied on 12 orally disintegrating tablets under USP dissolution medium 0.1N HCl and media pH 1.2, 4.5, 6.8 using UPS apparatus Type II at 50 rpm speed for 0.1N HCl USP medium and 75 rpm speed for pH 1.2, 4.5 and 6.8 media as follows:

  • The above-mentioned dissolution conditions were carried out in six vessels by placing six orally disintegrating tablets (one orally disintegrating tablet in each vessel). After 5, 10, 15, 20, 30, 45 and 60 minutes of dissolution, five ml of each sample were withdrawn and 5 ml of blank (dissolution media) were added to replace this withdrawn volume and achieve a constant dissolution media volume (500 ml) for USP medium and (900 ml) for pH1.2, pH4.5, pH6.8.
  • The withdrawn 5 ml was added in a coded labeled test tube at each sampling interval and then filtered through a (PTFE 0.45mm) syringe membrane filter.
  • On a further six orally disintegrating tablets, the previously mentioned procedures were repeated.
  • The filtered samples were then injected into the HPLC-UV for drug quantification at 280 nm.

Results

  Risperidone quantification was done by reverse phase HPLC using an eluting solvent consisting of 0.1 percent TFA pH 3: acetonitrile (70: 30 V/V). The eluting solvent was filtered using a nylon membrane filter (pore size 0.45µ) and degassed for 10 minutes on sonicator. A C8 column (Waters Symmetry 150X4.6 mm, particle size 5um) was used to achieve chromatographic separation, the eluting solvent flow rate was 1 ml/min. Parameters of system suitability, such as theoretical plates, were above 4000 and the tailing factor was less than 1.3.

Method validation

  Following the analytical method development, the method was validated following FDA and ICH guidelines [16,17] Standard procedures to evaluate required validation items were followed.

Specificity

  Bank solvent samples were injected and no drugs were detected (Figure 1). The drug was unstable under alkaline conditions (Figure 2) and was degraded. The drug was degraded to about 81% under acidic conditions (Figure 3). In neutral conditions, risperidone was more stable when the drug was refluxed with water for 1 h, and there was almost no degradation (Figure 4). The stability of the stock solution under conditions (2 to 8oC) was assessed by risperidone quantification and comparison with the freshly prepared standard solution (Figure 5). No remarkable change occurred in the stock solution response, in comparison to freshly prepared standard.

Figure 1: Chromatogram of Blank solvent.

Figure 2: Chromatogram of Risperidone Stress NaOH.

Figure 3: Chromatogram of Risperidone Stress HCL.

Figure 4: Chromatogram of Risperidone Stress Heat.

Figure 5: Chromatogram of Standard Risperidone.

  All forced degradation samples were analyzed under the above HPLC conditions to monitor the homogeneity and purity of the risperidone peak. There was no interference with individual related substances, placebo and risperidone, thus providing a specific analytical method.

Linearity

  Risperidone showed linearity from 0.2 to 6 µg/ml in USP medium and from 0.1 to 3.4 µg/ml in dissolution medium pH 1.2, 4.5, and 6.8 with (r2 = 0.999) for HPLC. Linearity was assessed in triplicate by the determination of eight standard concentrations within range of 0.2 to 6 μg/ml using USP medium 0.1NH HCl and within range of 0.1 to 3.4 μg/ml using media pH 1.2, pH 4.5 and pH 6.8 as solvent. Peak areas of risperidone were plotted versus the concentration of risperidone (μg/ml) and linear regression analysis was conducted (Table 1). High correlation coefficient (r2) and low intercept CV% value (less than 5%) indicate validation of analytical method linearity. The resultant chromatogram demonstrated symmetrical and well-separated peak at 4.1 min (Figure 2).

Analyte Risperidone

Range

0.2 to 6 µg/mL

Linearity correlation equation

At Dissolution medium (0.1N HCl)

Y = 70477.4315800x + 140.6587692

Range

0.1 to 3.4 µg/mL

Linearity correlation equation

At Dissolution medium (pH1.2)

Y = 72852.0412024x + 97.6381552

At Dissolution medium (pH4.5)

Y = 53041.2955702x - 193.3467121

At Dissolution medium (pH6.8)

Y = 43505.4467602x + 99.7584606

Linearity correlation coefficient R2

At Dissolution medium (0.1N HCl)

0.9999312

At Dissolution medium (pH1.2)

0.9999803

At Dissolution medium (pH4.5)

0.9999906

At Dissolution medium (pH6.8)

0.9999905

Mean Slope ±SD

At Dissolution medium (0.1N HCl)

70477.432 ± 292.578

At Dissolution medium (pH1.2)

72852.041 ± 682.252

At Dissolution medium (pH4.5)

53041.296 ± 9.081

At Dissolution medium (pH6.8)

43505.447 ± 69.162

Mean Intercept ± SD

At Dissolution medium (0.1N HCl)

140.659 ± 223.003

At Dissolution medium (pH1.2)

97.638 ± 567.187

At Dissolution medium (pH4.5)

-193.347 ± 94.999

At Dissolution medium (pH6.8)

99.758 ± 90.253

Standard error of slope

At Dissolution medium (0.1N HCl)

168.920

At Dissolution medium (pH1.2)

393.898

At Dissolution medium (pH4.5)

5.243

At Dissolution medium (pH6.8)

39.931

Standard error of intercept

At Dissolution medium (0.1N HCl)

128.751

At Dissolution medium (pH1.2)

327.466

At Dissolution medium (pH4.5)

54.848

At Dissolution medium (pH6.8)

52.107

Table 1: Linearity Results
Where, n = 3, average of three determinations, SD (±): standard deviation.

Precision

  Intra-day variations can be expressed in terms of CV%. Values of CV% in dissolution medium USP (0.1N HCl), pH 1.2, 4.5, and 6.8 have been shown to be less than or equal to 2%, revealing good precision. The mean CV% for dissolution medium USP (0.1N HCl), pH 1.2, 4.5, and 6.8 were 0.850, 0.303, 0.790, and 0.083%.

Detection Limit (LOD) and quantitation limit (LOQ)

  The LOD and LOQ of the method were determined by the injection of gradually low concentrations of standard solutions using the HPLC method developed. The detection Limit for risperidone was 0.010, 0.026, 0.006, and 0.007µg/mL for dissolution media 0.1N HCl, pH 1.2, pH 4.5, and pH 6.8 respectively. The quantitation limit was 0.032, 0.078, 0.018, and 0.02µg/ml for dissolution media 0.1N HCl, pH 1.2, 4.5, and 6.8 respectively.

Assay (Potency) of risperidone

  The developed method was used for risperidone assay in the tablet formulations. Results were found out as mean % recovery 100.113% for risperidone reference orally disintegrating tablet. The results indicating that the method is selective for the assay of risperidone with no interference from the inactive ingredients.

Content uniformity of risperidone

  The developed method was applied for content uniformity of risperidone in an orally disintegrating tablet dosage form. Results were found out as a mean recovery of 100.564%. The acceptance value was 1.856 for risperidone reference orally disintegrating tablet.

Dissolution of risperidone

  The developed method was used for dissolution testing of risperidone orally disintegrating tablet. Results were found out as a dissolution profile for mean percentage drug dissoluted of risperidone in Reference tablets. Results have shown that the reference product complies with the FDA and BCS Guidelines [18] and the United States Pharmacopeia Regulations (USP) [19].

  The results of risperidone 2mg orally disintegrating tablet dissolution % in 0.1N HCl (USP medium) after 5, 10, 15, 20, 30, 45, and 60 minutes were 77.894, 82.604, 86.179, 90.200, 93.794, 97.127, 99.258% respectively.

  The results of risperidone 2mg orally disintegrating tablet dissolution % in medium pH1.2 after 5, 10, 15, 20, 30, 45, and 60 minutes were 80.554, 83.985, 86.216, 88.166, 89.839, 91.673, 93.769% respectively.

  The results of risperidone 2mg orally disintegrating tablet dissolution % in medium pH4.5 after 5, 10, 15, 20, 30, 45, and 60 minutes were 90.544, 92.959, 94.200, 94.965, 95.936, 96.540, 97.849% respectively.

  The results of risperidone 2mg orally disintegrating tablet dissolution % in medium pH6.8 after 5, 10, 15, 20, 30, 45, and 60 minutes were 59.228, 71.606, 82.841, 84.923, 89.663, 92.805, 96.908% respectively.

   Results of method validation, assay, and dissolution indicate that the method validation and drug product complies with the specified requirements and will therefore provide the required clinical benefit in the management of schizophrenia, bipolar mania, and autistic disorder associated irritability.

Discussion

  It should be noted that the estimation and testing of risperidone in pharmaceutical products, including tablets, and the assessment of its in vitro performance, including dissolution using a validated methodology, are important for ensuring the therapeutic effectiveness of risperidone.

  As shown previously, the clinical importance of risperidone as an antipsychotic drug in the treatment of schizophrenia, and bipolar mania with a better clinical effect than first-generation antipsychotics [1,2]. Besides, it improves autistic disorder associated irritability symptoms in children and adolescents, and has a good safety profile [1] And aid in managing dementia symptoms like aggression, psychosis, and agitation [4].

  Many analytical methods have been developed for the quantification of risperidone in pharmaceutical products. An HPLC method was developed for the assessment of risperidone in tablet formulations. C18 250×4.6 mm, 5 μm column was used. Solvent elution was in isocratic mode. The mobile phase of methanol: acetonitrile: 50 mM phosphate buffer (80: 10: 10 V/V/V) was used at flow 1.3 ml/min. UV detector wavelength was set at 234 nm. The LOD and LOQ values were 0.5 and 0.99 ug/ml respectively [6].

  Another validated stability-indicating assay method for risperidone was developed. Chromatography was achieved using C18 column 250 mm×4.6 mm and eluting solvent of methanol and acetonitrile (80: 20, V/V) at 1 ml/min flow rate. detection was performed at UV 280 nm. The method showed linearity within the range of 10 to 60 μg/ml, and r2 0.998. LOD 1.79μg/ml and LOQ 5.44μg/ml [9].

  The analytical method for risperidone determination was developed as follows. Chromatography was performed using C8 DB column 25cm × 0.46 cm, 5 μm p.s., at 40°C and the eluting solvent ratio of 100 mM amm. acetate pH 5.5: methanol (40:60 V/V) and 1ml/min flow rate, and 274 nm UV detection wavelength. Method linear was from 4.0 to 275 µg/ml, and r2 0.9998. LOD 0.48 μg/ml and LOQ 1.59 μg/ml. The precision was below 3.27%, while accuracy was 99.00 to 101.12% [14].

  Another HPLC method was developed for the estimation of risperidone in bulk and dosage forms. C18 column was used with an eluting solvent of water: methanol 35: 65 V/V (PH 5.5). wave length of 276nm was used for detection. The method demonstrated good linearity r2 0.999. LOD 7.53µg/ml and LOQ 2.48µg/ml [15].

  The HPLC – UV method used in this study was convenient and of highly sensitive, specific, precise and accurate. Materials and reagents used for analysis are common, suitable and available, such as C8 column 150mm X 4.6mm, TFA and Acetonitrile. Eluting solvent was isocratically pumped, and the total run time was 5.1 minutes. This allows analysis of up to 250 samples per 24 hours. The method showed an advantage over the reported methods regarding the Lower limit of quantitation [6,9,13-15].

  The standard curve using 0.1N HCl as a solvent showed linearity over the range of 0.2 to 6µg/ml and LOQ of 0.032µg/ml. And using pH 1.2, 4.5, and 6.8 media as a solvent was linear over the range of 0.1 to 3.4 µg/ml and LOQ was 0.078, 0.018, and 0.02µg/ml respectively. r2 was equal to 0.999, accuracy of the results was within the range of 98 - 102%, and analytical precision was below 2% which is following FDA and ICH guidelines [10,11]. The intercept value standard deviation was below 5%, number of theoretical plates higher than 4000, tailing factor below 1.3, and so it can be used to determine risperidone in pharmaceutical formulations.

  The method is appropriate for use in the routine quality control of distributed risperidone products in the market in order to guarantee adherence of distributed products under various storage circumstances in hospitals and pharmacies with specifications, absence of probable degradative product formation, and reduction of active ingredient quantity in the dosage form, and safe administration of risperidone products with no side effects, and avoiding lack of clinical efficacy.

Conclusion

  The HPLC analytical method developed for the quantification of risperidone in pharmaceutical formulations enables a specific, accurate and precise analysis of risperidone. The developed analytical method has shown sufficient sensitivity for quantification of risperidone in pharmaceutical formulations and therefore can be used for routine analysis, quality control and stability studies of pharmaceuticals, thereby guaranteeing safe and effective management of schizophrenia.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Scott LJ and Dhillon S. “Risperidone: a review of its use in the treatment of irritability associated with autistic disorder in children and adolescents”. Paediatric Drugs5 (2007): 343-354.
  2. Madaan V., et al. “Clinical utility of the risperidone formulations in the management of schizophrenia”. Neuropsychiatric Disease and Treatment 7 (2011): 611-620.
  3. Grant S and Fitton A. “Risperidone. A review of its pharmacology and therapeutic potential in the treatment of schizophrenia”. Drugs2 (1994): 253-273.
  4. Yunusa I and El Helou ML. “The Use of Risperidone in Behavioral and Psychological Symptoms of Dementia: A Review of Pharmacology, Clinical Evidence, Regulatory Approvals, and Off-Label Use”. Frontiers in Pharmacology 11 (2020): 596.
  5. Z Song and C Wang. “Sensitive chemiluminescence assay for risperidone in pharmaceutical preparations”. Journal of Pharmaceutical and Biomedical Analysis3 (2004): 491-494.
  6. S Bladania., et al. “RP-HPLC estimation of risperidone in tablet dosage forms”. Indian Journal of Pharmaceutical Sciences4 (2007): 494-497.
  7. SK Patel and N J Patel. “TLC determination of amitriptyline HCl, trifluoperazine HCl, risperidone and alprazolam in pharmaceutical products”. Chromatographia3-4 (2009): 393-396.
  8. A Goyal and I Singhvi. “Visible spectrophotometric determination of aceclofenac in tablet formulation”. Asian Journal of Chemistry4 (2006): 3157-3159.
  9. Zarna R Dedania., et al. “Stability Indicating HPLC Determination of Risperidone in Bulk Drug and Pharmaceutical Formulations". International Journal of Analytical Chemistry 6 (2011).
  10. ICH HARMONISED TRIPARTITE GUIDELINE. Validation of Analytical Procedures: Text and Methodology Q2 (R1) (2005).
  11. S. Department of Health and Human Services Food and Drug Administration, Guidance for Industry, Analytical Procedures and Methods Validation for Drugs and Biologics (2015).
  12. S. Department of Health and Human Services Food and Drug Administration, Guidance for Industry Waiver of in Vivo Bioavailability and Bioequivalence Studies for Immediate-Release Solid Oral Dosage Forms Based on a Biopharmaceutics Classification System (2017).
  13. Risperidone orally disintegrating tablets, USP35.
  14. Ashour S and Kattan N. “Sensitive method for the quantitative determination of risperidone in tablet dosage form by high-performance liquid chromatography using chlordiazepoxide as internal standard”. International Journal of Biomedical Science 2 (2013): 91-97.
  15. Bhavana A Kokane., et al. “RP-HPLC Method Development and Validation for Estimation of Risperidone in Bulk and Dosage Forms”. International Journal of Pharmaceutical Sciences Review and Research 1 (2019): 29-32.

Citation

Citation: Nagwa A Sabri., et al. “Development of a Novel Method for Determination of Risperidone in Pharmaceutical Products and its Quality Control Application". Acta Scientific Paediatrics 5.3 (2021): 101-109.




Metrics

Acceptance rate33%
Acceptance to publication20-30 days
Impact Factor1.197

Indexed In




News and Events


  • Certification for Review
    Acta Scientific certifies the Editors/reviewers for their review done towards the assigned articles of the respective journals.
  • Submission Timeline for Upcoming Issue
    The last date for submission of articles for regular Issues is December 25, 2024.
  • Publication Certificate
    Authors will be issued a "Publication Certificate" as a mark of appreciation for publishing their work.
  • Best Article of the Issue
    The Editors will elect one Best Article after each issue release. The authors of this article will be provided with a certificate of "Best Article of the Issue"

Contact US