Acta Scientific Medical Sciences (ASMS)(ISSN: 2582-0931)

Review Article Volume 6 Issue 5

Risks and Uncertainties in Photobiological Measurements

Yun Zhang*

Belarusian National Technical University, Minsk, Republic of Belarus

*Corresponding Author: Yun Zhang, Belarusian National Technical University, Minsk, Republic of Belarus.

Received: February 28, 2022; Published: April 18, 2022

Abstract

The risks and uncertainties in photobiological measurements have attracted more attention. Positive and negative effects of optical radiation on the visual analyzer, skin and psychophysiological functions of the human body have been established. Herein, standardized the quantities of optical radiation in 5 systems. Additionally, photobiological quantities and the traceability of their measurements were investigated. The risks and uncertainties of photobiological measurements were analyzed with the example of weighted radiance (LB). Combining the influence of optical radiation on human body, the map of safety intervals was creatively proposed, and the connection between uncertainty and photobiological measurement has been established.

Keywords: Photobiological Risks; Photobiological Measurements; Optical Values; The Map of Safety Intervals; Traceability; Uncertainty

References

  1. CIE S 017/E: 2020: ILV: International Lighting Vocabulary, 2nd
  2. ISO 21348: 2007, Space environment (natural and artificial) - Process for determining solar irradiances. (This standard was last reviewed and confirmed in 2021).
  3. Журавков НМ. “Частные и глобальные риски при эксплуатации светотехнических изделий”. Н. М. Журавков, Е. Н. Савкова, Ю. Чжан // Современные технологии для заготовительного производства [Электронный ресурс]: сборник научных работ Республиканской научно-технической конференции профессорско-преподавательского состава, научных работников, докторантов и аспирантов МТФ БНТУ (14 апреля 2021 г.) / сост. А. П. Бежок. – Минск: БНТУ (2021): 126-128.
  4. Mark D Fairchild. “Color Appearance Models [M]”. Munsell Color Science Laboratory, Rochester Institute of Technology, USA. Second Edition (2005).
  5. Международная система единиц (SI). издание 9-е/2019 г. Федеральное Агентство по техническому регулированию и метрологии. – Москва: Росстандарт (2019): 100.
  6. SI Brochure - 9th edition (2020) - Appendix 3. Units for photochemical and photobiological quantities (2021).
  7. Júnia R., et al. “Growth hormone: isoforms, clinical aspects and assays interference”. Clinical Diabetes and Endocrinology4 (2018).
  8. CIE TN 003: 2015 Report on the First International Workshop on Circadian and Neurophysiological Photometry (2013): 35.
  9. ISO Guide 73: 2009 (en) Risk management — Vocabulary.
  10. ГОСТ IEC 62471-2013. Фотобиологическая безопасность ламп и ламповых систем.
  11. Berson DM., et al. “Phototransduction by retinal ganglion cells that set the circadian clock”. Science 295 (2002): 10.

Citation

Citation: Yun Zhang. “Risks and Uncertainties in Photobiological Measurements". Acta Scientific Medical Sciences 6.5 (2022): 109-114.

Copyright

Copyright: © 2022 Yun Zhang. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.




Metrics

Acceptance rate30%
Acceptance to publication20-30 days
Impact Factor1.403

Indexed In





Contact US