Clinical Precision in Managing Fractured Implant Screws: A Case Report

G Rishitha Reddy, Gaddam Divya, Namratha Sai Bolla and Sreenivas Nagarakanti*

Department of Periodontology, Narayana Dental College and Hospital, Andhra Pradesh, India

*Corresponding Author: Sreenivas Nagarakanti, Department of Periodontology, Narayana Dental College and Hospital, Andhra Pradesh, India.

Received: January 15, 2025; Published: January 26, 2025

Abstract

Dental implants are considered to be one of the effective methods for replacing missing teeth, which poses high success rates. However, complications, while infrequent, are inevitable. One notable complication is the fracture of abutment screws, which constitutes significant challenges, particularly when retrieving the fractured screw from the implant fixture. This case report illustrates two clinical scenarios of abutment screw fractures that were successfully treated with a manufacturer-designed implant screw retrieval kit. In both cases, the retrieval process preserved internal threads, ensuring structural integrity of the implant. This report emphasizes the effectiveness of specialized screw retrieval kits as an innovative alternative to traditional methods. These kits safeguard the implant's structural integrity while minimizing patient costs, emphasizing their importance in modern implantology.

Keywords: Dental Implant; Screw Fracture; Screw Retrieval; Screw Retrieval Kit; Abutment Screw

References

  1. Kochar Shraddha P., et al. “The etiology and management of dental implant failure: a review”. Cureus10 (2022).
  2. Hassan Mohajerani., et al. “The risk factors in early failure of dental implants: a retrospective study”. (2017): 298-303.
  3. Nayana Prabhu., et al. “Retrieval of fractured implant abutment screws: a narrative review”. Journal of International Society of Preventive and Community Dentistry3 (2022): 287-294.
  4. Cheng Feng-Chou., et al. “Removal of a fractured abutment screw within the implant body: A case report”. Journal of Dental Sciences4 (2023): 1945.
  5. Raju Soja., et al. “Management of perishing implants with abutment screw fracture-A systematic review”. The Journal of Indian Prosthodontic Society3 (2021): 229-239.
  6. Chowdhary R., et al. “Implant abutment screw fracture and techniques of retrieval: a literature review based on a novel abutment screw fracture classification”. Journal of Osseointegration1 (2023): 32-39.
  7. Rajan R., et al. “Conservative Retrieval of Fractured Abutment Screw-A Case Report”. JSM Dental Surgery1 (2021): 1033.
  8. Satterthwaite J and L Rickman. "Retrieval of a fractured abutment screw thread from an implant: a case report”. British Dental Journal 4 (2008): 177-180.
  9. Gooty Jagadish Reddy., et al. “Noninvasive method for retrieval of broken dental implant abutment screw”. Contemporary Clinical Dentistry2 (2014): 264-267.
  10. Joshi Aniruddha., et al. “An unconventional approach for retrieval of fractured prosthetic screw: A case report”. Journal of Osseointegration 3 (2018): 75-78.
  11. Türkyılmaz İlser., et al. “Removal of a fractured locator abutment screw fragment”. The Journal of Contemporary Dental Practice5 (2013).
  12. Nergiz Ibrahim., et al. “Removal of a fractured implant abutment screw: a clinical report”. The Journal of Prosthetic Dentistry 6 (2004): 513-517.
  13. Yi Yuseung., et al. “Comparison of implant component fractures in external and internal type: A 12-year retrospective study”. The Journal of Advanced Prosthodontics2 (2018): 155-162.
  14. Harshakumar K., et al. “Salvaging an implant with abutment screw fracture by a custom titanium post and core supported prosthesis-a novel technique”. International Journal of Scientific Study1 (2014): 36-39.

Citation

Citation: Sreenivas Nagarakanti., et al. “Clinical Precision in Managing Fractured Implant Screws: A Case Report". Acta Scientific Dental Sciences 9.2 (2025): 64-67.

Copyright

Copyright: © 2025 Sreenivas Nagarakanti., et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.